HP 12500 Series Installation Manual page 84

Routing switch
Table of Contents

Advertisement

Field
Transceiver info I/O error
Transceiver info checksum error
Transceiver type and port configuration mismatch
Transceiver type not supported by port hardware
# Display the currently measured values of the fault detection parameters of the transceiver plugged in
interface GigabitEthernet 3/0/2.
<Sysname> display transceiver diagnosis interface gigabitethernet 3/0/2
GigabitEthernet3/0/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C)
Voltage(V)
36
3.31
Table 26 Command output
Field
transceiver diagnostic information
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBm)
TX power(dBm)
Remarks
Transceiver information read and write error
Transceiver information checksum error
The type of the transceiver module does not match the
port configuration.
The port does not support this type of transceiver
modules.
Bias(mA)
RX power(dBm)
6.13
-35.64
Description
Digital diagnosis information of the transceiver module on the
interface.
Digital diagnosis parameter—Temperature, in °C, accurate to 1°C.
Digital diagnosis parameter—Voltage, in V, accurate to 0.01 V.
Digital diagnosis parameter—Bias current, in mA, accurate to 0.01
mA.
Digital diagnosis parameter—RX power, in dBm, accurate to 0.01
dBm.
Digital diagnosis parameter—TX power, in dBm, accurate to 0.01
dBm.
78
TX power(dBm)
-5.19