Journal Mode - SATO TH2 Series Operator's Manual

Hide thumbs Also See for TH2 Series:
Table of Contents

Advertisement

8.3 OPERATION MODE SELECTION (cont'd)

8.3.6 Journal Mode

The Journal mode is identical to Continuous mode, except that neither the gap nor the I-Mark sensor is
enabled. The Sensor Type is set to None or Fix, in Continous mode. This means that the media is fed long
enough for all data to be printed regardless of any gaps or I-Marks.
In the figure below, n labels are printed (where n is equal to 1 or more).
Before printing, label number 1 is in the printing start position.
When all n labels are printed, label number n+1 is in the printing start position.
Before
printing
After
printing
n labels
The size of the labels in the figure above differs. This is to indicate that normally in Journal mode, the size
depends on the data printed.
It is possible to set a fixed label length in Journal mode. In this case, the media will be fed according to this
length.
TH2 Series Operator Manual
3
2
n+3
n+2
Print head
direction
1
n
n+1
Section 8: Appendix
Feed
Page 8-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents