Power Connector - Cisco Catalyst IW6300 Series Hardware Installation Manual

Heavy duty access point
Hide thumbs Also See for Catalyst IW6300 Series:
Table of Contents

Advertisement

Power Connector

Figure 3: W-6300H Access Point Console Port and Reset Button
1
Inspect the seal of the plug and properly tighten it at the time of installation, and also every time the plug is
removed and replaced. Tighten the plug to 5-6 lb-ft. If you do not tighten the plug properly, it will not meet
IP66/67 criteria, and may lead to water leaking into the unit.
Power Connector
The following figure shows the power connector of access point model IW-6300H-AC-x-K9.
Figure 4: Power Connector of Access Point Model IW-6300H-AC-x K9
1
The following figure shows the power connector of access point model IW-6300H-DCW-x-K9.
Cisco Catalyst IW6300 Heavy Duty Series Access Point Hardware Installation Guide
6
Console port
2
AC Power-IN
2
Overview
Reset button
Internal ground

Hide quick links: