General Notes On The Cabling In Tcs Video Systems; Terms For 5 Wire And 6 Wire Operation; Wire Operation - TCS AVU14 0 Series Product Information

Front-door station series with colour-video for flush-mount
Table of Contents

Advertisement

General notes on the cabling in TCS video systems

Terms for 5 wire and 6 wire operation

6 wire operation

5 wire operation
6 wire operation
The cabling depends on the building situation and is only limited by its length.
• When selecting the cable length consider: the loop resistance M-P must be max. 8 Ω
(table 1).
• For loop resistance > 8 Ω: provide for multiple wiring of the lines (twisted pairs).
• choice of line or star wiring
• Do not use more than 6 video in-house stations per line. For systems with more video
in-house stations provide for the use of video distributors (VT02, VT04).
• up to 64 front-door stations and an almost unlimited number of in-house stations can be
connected polarity-free (a/b) to a system. (use suitable power supply and control unit.)
Table 1: Loop resistances
Line length M-P
in m
10
20
30
40
50
60
70
80
90
100
5 wire operation
Number of monitors
in the system
24
12
6
TCS TürControlSysteme AG • Geschwister-Scholl-Str. 7 • 39307 Genthin
Phone.: +49 39 33 / 87 99 10 • Fax: +49 39 33 / 87 99 11 • www.tcs-germany.com
standard operating mode. Video operation where two separate
earths (b and M) are being used.
special operating mode. Video operation where b and M are joined to
a single earth.
1.22
2.45
3.67
4.90
6.12
7.35
max. permissible loop
resistance
4,8
6,3
8
4
Line diameter
0.6 mm
Loop resistance in Ω
0.69
1.38
2.07
2.76
3.44
4.13
4.82
5.51
6.20
6.89
in Ω
0.8 mm
Subject to change without notice.