Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual page 515

Hide thumbs Also See for PRIMERGY TX2550 M4:
Table of Contents

Advertisement

The minimum startup configuration consists of the following components and
cables:
Components
System board
1 CPU with CPU heat sink
1 memory module
Front panel module
1 PSU
Table 4: Minimum startup configuration - components
Cables
Front panel cable
Power cable
Table 5: Minimum startup configuration - cables
"Shutting down the server" on page 52
Ê
"Disconnecting the power cord" on page 53
Ê
Ê Take the system down to its minimum startup configuration.
"Connecting the power cord" on page 81
Ê
Ê Connect a display to the server.
Ê Switch on the server, see section
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
TX2550 M4
Notes
no TPM or expansion cards installed
installed in CPU slot CPU 1
installed in DIMM slot 1A
without connected USB3.0
installed in PSU bay PSU 1
Notes
connected to system board
"Switching on the server" on page
Upgrade and Maintenance Manual
Appendix A
82.