Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual page 476

Hide thumbs Also See for PRIMERGY TX2550 M4:
Table of Contents

Advertisement

Converting a floorstand model to a rack model
Figure 340: Securing the accessible drive cage (B)
Ê Carefully turn the server upside down.
I
At least two people are needed to turn over a fully equipped server.
Remove HDDs and PSUs in order to facilitate the task.
Ê Secure the accessible drive cage with the two screws (see circles) to the
bottom side of the server.
I
Note the correct screw positions: The screw hole on the right that has
been used in the floorstand configuration remains empty.
Ê Install the front panel module, see section
on page
410.
Ê If applicable, install all accessible drives, see section
accessible drive" on page
Ê If applicable, install an HDD extension box, see section
extension boxes" on page
Preparing the intrusion switch
Ê Remove the intrusion switch module, see section
switch cable" on page
Ê Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and
reinstall the intrusion switch module, see section
switch cable" on page
476
379.
241.
482.
485.
Upgrade and Maintenance Manual
"Installing the front panel module"
"Installing an
"HDD/SSD
"Removing the intrusion
"Installing the intrusion
TX2550 M4