System board and components
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Please proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function
key to enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the Global Error indicator stops flashing.
"Updating or recovering the BIOS and iRMC" on page 111
Ê
I
When updating to BIOS 1.15.0 or higher with Red Hat Enterprise
Linux 7 as operating system, a network name for onboard LAN,
as well as for the OCP connectors may change.
Inform the customer about the changes.
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, see the
corresponding BIOS Setup Utility Reference Manual.
"Verifying system information backup/restore" on page 113
Ê
"Verifying the system time settings" on page 123
Ê
"Looking up changed MAC/WWN addresses" on page 129
Ê
"Updating the NIC configuration file in a Linux and VMware environment" on
Ê
page 126
"Resuming BitLocker functionality" on page 127
Ê