10. Maintenance
W
ARNING
sembly. Never place or mount objects that may obstruct or prevent the air circulation !
Filter location
The filters are located at the air entrance (below the optical engine). They are accessible from the front of the projectors. This
implies:
•
In case of a front configuration : the front plate has to be removed : 8 hexagonal screws
•
In case of a rear configuration: the front polar plate has to be removed : 3 flat screws
Image 10-3
VR Workroom rear configuration : Front plates
Necessary tools
•
flat screwdriver
•
Allan key (M8)
How to access the projector's front section ?
1. Remove the indicated screws (depending on the configuration, front or rear) (image 10-5, image 10-6)
Image 10-5
Front plate screws (8) in a rear configuration
Refer to the filter cleaning/replacement procedure in the iCon service manual.
50
:
To insure optimal cooling of the projectors always insure a minimal safety zone around the as-
Image 10-4
Image 10-6
Front plate screws (3 flat screws) )in a front configuration
R5976989 BARCO VR WORKROOM 22/09/2006