Changing The Needle Holder - DURKOPP ADLER 745-35-10 S Service Instructions Manual

Hide thumbs Also See for 745-35-10 S:
Table of Contents

Advertisement

Machine head

3.8.9 Changing the needle holder

Fig. 31: Changing the needle holder (1)
(1) - Hex key
(2) - Screw
Information
A needle holder cannot be replaced unless the corresponding needle bar
is at bottom dead center.
The other needle bar must be disconnected.
To change the needle holder:
1. Loosen the screw (3).
2. Remove the needle from the needle holder (4).
3. Use a hex key (1) to press down and hold the switch rod of the needle bar.
4. Turn the handwheel to disconnect the needle bar.
5. Continue to turn the handwheel.
 The actuated needle bar switches off.
6. Keep turning the handwheel until the needle bar is at bottom dead
Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
WARNING
Risk of injury from moving parts!
Crushing possible.
Do not check and replace the needle holder unless
the sewing unit is switched off.
center.
(3) - Screw
(4) - Needle holder
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

745-35-10 a

Table of Contents