Table 4-2. Normal Mode Error-Free Led States - Bay Networks 8000 RAC Installing Manual

Remote access concentrator
Table of Contents

Advertisement

Activity N1: Testing
LEDs
Activity N2: Testing
the Hardware

Table 4-2. Normal Mode Error-free LED States

Activity
N1: LEDs OK
N2: Hardware OK
Key:
On continuously
Off
All front-panel LEDs (and the Link LED on the rear panel) light for a
few seconds, then all turn off, confirming that all LEDs are operational.
During the power-up sequence, the RAC runs a series of self-test
diagnostics. These diagnostics test internal hardware functions. If a test
fails, the ATTN and STAT LEDs flash and an error message is displayed
on the console port. The TRAF LED flashes during the power-up self-
tests. After the self-tests complete, only the STAT and TRAF LEDs
remain on.
Normal Mode Error Sequence
Table 4-3
shows the state of the LEDs when an error occurs at various
stages of the start-up process. If the RAC fails during the hardware-test
state (N2), the error condition is hardware failure NE2. A description of
possible causes and solutions for each error condition follows.
Installing the Model 8000 Remote Access Concentrator
Chapter 4
Troubleshooting Procedures
STAT
ATTN
Green
Amber
TRAF
Green
4-5

Advertisement

Table of Contents
loading