4.2
minimum framing requirements
APPLICABLE FOR EXTERIOR AND REMOTE EXTERIOR INSTALLATIONS
note:
For optimal performance, we recommend installing DHC™ Plus within the top 12" (30.5cm) of the enclosure.
The DHC™ Plus must be mounted above the appliance.
DHCP-EK
Vent pipe, collars, firestops, etc.
1. Determine the desired location of the exterior housing assembly on the exterior wall, and then frame a 14 1/2"
(36.8cm) wide by 17 1/4" (44cm) high opening (Fig. 1).
Interior
Interior
Exterior
Exterior
2. Determine the desired amount of protrusion from the finished exterior wall, and then fasten the wall flashing
using 4 screws (supplied) (Fig. 2). See "mounting options" section for details.
note:
The exterior housing assembly MUST be pre-drilled
with a 1/8" drill bit before installing the wall flashing.
To avoid scratches, we recommend sliding the wall
flashing on from the back.
If surface-mounting your DHC™ Plus, this step is
not required (see "mounting options" section).
Minimum Clearance to Combustibles
exterior installation
Clearance
0"
1" (25mm)
14 1/2" (36.8cm)
17 1/4" (44cm)
note:
It may be necessary to shim the
blower housing in the rough opening
to provide a secure fit. If the blower
is not secured properly, excessive
noise and vibration may result.
Fig. 1
x 4
Fig. 2
W415-1789 / C / 01.29.19
EN
11