Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting page 72

Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant
Hide thumbs Also See for 48FC Series:
Table of Contents

Advertisement

DISPLAY TEXT
NEW HARDWARE (cont)
ENTHALPY SW CHAN
FAN STAT CHANNEL
IAQ OVERIDE SW CH
PHASE MON CHANNEL
NETWORK SETTINGS
BAS PROTOCOL
NETWORK TIMEOUT
CCN
BUS NUMBER
CCN ELEMENT #
CCN BAUDRATE
BROADCAST ACK?
BROADCAST SCHEDL?
BROADCAST TIME?
BROADCAST OAT?
BROADCAST OARH?
BROADCAST OAQ?
BROADCAST IAQ?
ALLOW G. OVERRIDE
LOCATION
REFERENCE NUMBER
BACNET
MAC ADDRESS
BACNET BAUDRATE
AUTO ID SCHEME
BACNET AUTO ID
BACNET ID
LINKAGE SETTINGS
DEVICE IAQ
OBJECT ID IAQ
COV IAQ
DEVICE OAQ
OBJECT ID OAQ
COV OAQ
DEVICE OARH
OBJECT ID OARH
COV OARH
DEVICE OAT
OBJECT ID OAT
COV OAT
DEVICE RARH
OBJECT ID RARH
COV RARH
APPENDIX A: SystemVut Controller Display
Settings Main Menu Layout (cont)
EXPANDED DISPLAY TEXT
Quick Menu for New Hardware
Enthalpy Sw Channel
Fan Status Channel
IAQ override sw channel
Phase Monitor Channel
Building Network Configurations Menu
BAS Protocol Select
Network Input Timeout
CCN Network Configuration Menu
CCN Bus Number
CCN Element Number
CCN Baud Rate
CCN Broadcast Ack'er
Global Schedule Broadcst
CCN Time Broadcast
Broadcast OAT On Network
Broadcast OARH On Netwrk
Broadcast OAQ On Network
Broadcast IAQ On Network
Allow Global Overrides
Device Location
Reference number
BACnet network configuration menu
BACnet Device Macaddress
BACnet BMS baud rate
ALC Auto Id Scheme
BACnet ID Auto ID
BACnet ID Number
LINKAGE SETTINGS MENU
BACnet device for IAQ
Object instance for IAQ
Change of value for IAQ
BACnet device for OAQ
Object instance for OAQ
Change of value for OAQ
BACnet device for OARH
Object instance for OARH
Change of value for OARH
BACnet device for OAT
Object instance for OAT
Change of value for OAT
BACnet device for RARH
Object instance for RARH
Change of value for RARH
VALUES
UNITS
0=None,
1=MBB DI12,
2=MBB DI13,
3=MBB DI14,
4=MBB DI02,
5=MBB Y3
0=None,
1=MBB DI12,
2=MBB DI13,
3=MBB DI14,
4=MBB DI02,
5=MBB Y3
0=None,
1=MBB DI12,
2=MBB DI13,
3=MBB DI14,
4=MBB DI02,
5=MBB Y3
0=None,
1=MBB DI12,
2=MBB DI13,
3=MBB DI14,
4=MBB DI02,
5=MBB Y3
0=NONE,
x
1=CCN,
2=BACNET
0 to 600
min
0 to 239
1 to 239
0=9600,
1=19200,
2=38400
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
text
text
1 to 127
0=9600,
1=19200,
2=38400,
3=57600,
4=76800,
5=115200
Yes/No
Yes/No
0 to 4194302
0 to 4194303
0 to 9999
0 to 60
0 to 4194303
0 to 9999
0 to 60
0 to 4194303
0 to 9999
0 to 60
0 to 4194303
0 to 9999
0 to 60
0 to 4194303
0 to 9999
0 to 60
72
DEFAULT
POINT
0=NONE
ENTHCHAN
0=NONE
FNSTCHAN
0=NONE
IAQOCHAN
0: No FIOP
PMR_CHAN
3: FIOP
2=BACNET
BMS_CFG
30
NETINTO
0
CCNBUS
1
CCNADD
2=38400
BAUDENUM
No
CCNBCACK
No
CCN_GSBC
No
CCNBC
No
OATBC
No
OARHBC
No
OAQBC
No
IAQBC
Yes
GLBLOVER
DEV_LOC
REF_NUM
01
BAC_MAC
4=76800
BAC_BAUD
Yes
AUID
Yes
BAC_AUID
1610101
BAC_ID
1610100
DEVIAQ
1009
OBJIAQ
0
COVIAQ
1610100
DEVOAQ
1012
OBJOAQ
0
COVOAQ
1610100
DEVOARH
1022
OBJOARH
0
COVOARH
1610100
DEVOAT
1003
OBJOAT
0
COVOAT
1610100
DEVRARH
30
OBJRARH
0
COVRARH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents