DISPLAY TEXT
INDOOR FAN (cont)
Indoor Fan Configurations Menu
IDF HIGH COOL SPD
IDF High Cool Speed--- RPM
IDF FREE COOL SPD
IDF Free Cool Speed--- RPM
ECONOMIZER
Economizer Configurations Menu
VENT METHOD
Ventilation Method
ECON MAX POS
Econ Max Damper Position
ECON TRAVEL TIME
Economizer Travel Time
MINIMUM POSITION CONFIGS
Minimum Position Configurations menu
MIN POS @ MAX FAN
Econ Min at Max Fanspeed
MIN POS SPEED 1
Min Pos --- User Speed 1
MIN POS DAMP 1
Min Pos --- User Pos 1
MIN POS SPEED 2
Min Pos --- User Speed 2
MIN POS DAMP 2
Min Pos --- User Pos 2
MIN POS SPEED 3
Min Pos --- User Speed 3
MIN POS DAMP 3
Min Pos --- User Pos 3
FREE COOL CONFIGS
Free Cooling Specific Configurations
Menu
LOW COOL SAT SP
LowFree Cool SAT Setpnt
HIGH COOL SAT SP
High FreeCool SAT Setpnt
FREE COOL MAX OAT
Free Cooling Max OAT
FREE COOL MIN OAT
Free Cooling Min Temp
DIFF DRY BULB CTL
Diff. Dry Bulb Control
DIFF DB DEADBAND
Diff. Dry Bulb Deadband
ENTHALPY HI LIMIT
Max Enthalpy OA limit
DIFF ENTHALPY CTL
Diff. Enthalpy Control
ENTHALPY DEADBAND
Enthalpy Cross Deadband
UNOCCUPIED FREE COOL
Unoccupied Free Cooling Configs Menu
WHEN TO UNOCC FC
When to Unocc Free Cool?
UFC PREOCC TIME
UFC PreOcc Time
UFC LOW TEMP
Unocc Free Cool Low Temp
POWER EXHAUST CONFIGS
Power Exhaust Configurations Menu
PE1 RELAY CHANNEL
PE1 Relay Channel
PE1 POS @ MAX SPD
PE Stage 1 at Max speed
PE OFF DEADBAND
PE Turn Off Dead band
PE2 RELAY CHANNEL
PE2 Relay Channel
PE2 POS @ MAX SPD
PE Stage 2 At Max Speed
ECON ACT MECH DISC DIAG
Econ Actuator Mechanical disconnect
diagnostic menu
MDD--- H/C END DLY
T24 Heat/Cool End Delay
MDD--- MIN MOVE
T24Econ Min Move for SAT
MDD--- SAT DB
Damper SAT deadband
MDD--- MIN RAT--- OAT
T24 Min Diff in RAT--- OAT
MDD--- MIN TEST POS
T24 Test Minimum Pos
MDD--- MAX TEST POS
T24 Test Maximum Pos
Settings - - Main Menu Layout (cont)
EXPANDED DISPLAY TEXT
0 to 3000
0 to 3000
0=NONE,
1=ECON,
2=2POS DMPR,
3=ERV,
4=ECON ERV
0 to 100
5 to 300
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
40 to 80
40 to 80
0 to 90
--- 30 to 70
Enable/Disable
0 to 20
1 to 99
Enable/Disable
0 to 20
0=Disabled,
1=PreOcc,
2=Unocc
1 to 999
--- 30 to 70
0=NONE,
1=MBB RLY11,
2=MBB RLY06
0 to 100
0 to 100
0=NONE,
1=MBB RLY11,
2=MBB RLY06
0 to 100
0 to 60
10 to 20
0 to 20
5 to 20
0 to 100
0 to 100
VALUES
UNITS
RPM
1474: Size 04 Standard
1708: Size 04 Medium
1942: Size 04 High
1482: Size 05 Standard
1693: Size 05 Medium
1919: Size 05 High
2075: Size 05 High
1677: Size 06 Standard
1864: Size 06 Medium
2075: Size 06 High
2212: Size 06 High
1794: Size 07 Standard
1973: Size 07 Medium
2212: Size 07 High
RPM
same as IDF LOW
COOL SPD (page 136)
0: No FIOP
1: Economizer FIOP
2: Two Position
Damper FIOP
%
100
sec
150
%
30
%
0
%
0
%
0
%
0
%
0
%
0
° F
65
° F
55
° F
65
° F
0
Disable
° F
3
BTU/LB
28
Disable
BTU/LB
2
1=PreOcc
min
120
° F
50
0: no FIOP
2: FIOP
%
40
%
5
0=NONE
%
75
min
25
%
10
° F
12
° F
15
%
15
%
85
137
DEFAULT
POINT
ENTRY
RPM_HCL
Static Fan
Static Fan
Static Fan
Static Fan
Static Fan
Static Fan 230v
1 ph
Static Fan 230v
3ph, 460v, 575v
Static Fan
Static Fan
Static Fan 230v
1 ph
Static Fan 230v
3ph, 460v, 575v
Static Fan
Static Fan
Static Fan
RPM_FCL
VENTTYPE
DAMPMAX
ECONOTRV
MINP_MAX
MP_USPD1
MP_UPOS1
MP_USPD2
MP_UPOS2
MP_USPD3
MP_UPOS3
LCSASP
HCSASP
MAXFREET
MINFREET
DIFFBULB
OATRATDB
FREEMAXE
DIFFENTH
OAERAEDB
UFC_CFG
UFCTIME
OATLUFC
PE1_CHAN
PE1_PMAX
PE_OFFDB
PE2_CHAN
PE2_PMAX
T24CHDLY
T24ECSTS
T24SATDB
T24RATDF
T24TSTMN
T24TSTMX