DISPLAY TEXT
AIR QUALITY
Air Quality Configurations Menu
ANALOG IAQ CTRL
Analog Input IAQ Control
IAQ POS @ MAX SPD
IAQ Position at Max Fan
LOW AIR.Q DIFF
AQ Differential Low
HIGH AIR.Q DIFF
AQ Differential High
PREOCC PURGE ENBL
IAQ Preoccupancy Purge
PURGE POS @ MAX
IAQ Purge Pos at Max IDF
PREOCC LOW LIMIT
Preocc Purge Lockout OAT
PREOCC PURGE TIME
Preocc Purge Duration
AQ DIF HI--- IAQ OVR
AQ Diff High IAQOVERRIDE
AQ DIF LO--- IAQ OVR
AQ Diff Low--- IAQ OVERRIDE
IAQ OVRRD ENABLE
IAQ override enable
ALARM RELAY
Alarm Relay Configurations Menu
ALM RELAY CHANNEL
ALM Relay Assigned Chan
THERMOSTAT ALERTS
Thermostat Alerts
HARDWARE ALERTS
Hardware Failures Alerts
SAT/RAT ALERTS
SAT/RAT Sensor Alerts
OAT SENSOR ALERTS
OAT Thermistor Alerts
SPACE SENS ALERTS
Space Sensors Alerts
TRANSDUCER ALERTS
Transducer Sensor Alerts
RH SENSOR ALERTS
RH sensor failure Alert
CO2 SENSOR ALERTS
Air Quality CO2 Alerts
OACFM SENS ALERTS
OACFM Alarm Relay
ECONOMIZER ALERTS
Economizer Alerts
AIR FILTER ALERTS
Dirty Filter Alerts
GEN STATUS ALERTS
General Status Alerts
REFRIG CIR ALERTS
Refrig Circuit Alerts
COMPRESSOR ALERTS
Compressor Alerts
HEATING ALERTS
Heating Failure Alerts
INDOOR FAN ALERTS
Indoor Fan Alerts
ON ACTIVE FAULTS
Relay On Active Faults
SERVICE CONFIG MENU
Service Configuration Menu
CMP FRAMEWORK
Compressor Framework
SHUTDWN A1 FIRST
Comp A1 Shutdown First
SHUTDWN ALD FIRST
Comp Loader Shutdown 1st
IDF CURVE LO RPM
IDF Curve Low End RPM
Settings - - Main Menu Layout (cont)
EXPANDED DISPLAY TEXT
0=NO IAQ,
1=DCV,
2=IAQ OVRD,
3=CTRL MINP
0 to 100
0 to 5000
0 to 5000
Yes/No
0 to 100
0 to 70
5 to 120
0 to 5000
0 to 5000
Yes/No
0=NONE,
1=MBB RLY11,
2=MBB RLY06
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
0=1CIR 2CMP ,
1=1CMP+LDR,
2=1CMP
Yes/No
Yes/No
0 to 3000
VALUES
UNITS
0: no FIOP
1: FIOP
%
10
100
700
Yes
%
40
° F
50
min
15
PPM
700
PPM
100
No
1=MBB RLY11
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1: All except below
2: 48/50FC 04--- 06
No
Yes: All except below
No: 48/50FC 04--- 06
RPM
189: Size 04 Standard
219: Size 04 Medium
249: Size 04 High
190: Size 05 Standard
217: Size 05 Medium
246: Size 05 High
266: Size 05 High
215: Size 06 Standard
239: Size 06 Medium
266: Size 06 High
284: Size 06 High
230: Size 07 Standard
253: Size 07 Medium
284: Size 07 High
138
DEFAULT
POINT
ENTRY
IAQANCFG
IAQMINP
DAQ_LOW
DAQ_HIGH
IAQPURGE
IAQPMAX
IAQP_LA
IAQPTIME
AQD_HIGH
AQD_LOW
IAQOVREN
ALM_CHAN
TSTAT_AL
HW_AL
SATRATAL
OATRL_AL
SPACE_AL
TRANS_AL
RHS_AL
CO2S_AL
OACFM_AL
ECON_AL
FILT_AL
GENS_AL
CKT_AL
COMP_AL
HEAT_AL
FAN_AL
FAULT_AL
SYSVTYPE
SDWN_A1
SDWN_ALD
IFMLORPM
Static Fan
Static Fan
Static Fan
Static Fan
Static Fan
Static Fan 230v
1 ph
Static Fan 230v
3ph, 460v, 575v
Static Fan
Static Fan
Static Fan 230v
1 ph
Static Fan 230v
3ph, 460v, 575v
Static Fan
Static Fan
Static Fan