Installation sequence
Preparing for boiler installation
!
Please note
Avoid damaging the appliance.
Connect all pipework free of load and torque
stress.
480
G
A
B
C
D
EF
Fig. 1
Heating flow Rp
A
¾
Expansion vessel connection G
B
Cylinder flow G
C
¾
Cylinder return G
D
¾
E
Heating return Rp
¾
1. Prepare the water connections. Thoroughly flush
the heating system.
2. Prepare the oil connections (oil filter):
Single line filter (magnum filter bowl with large fil-
ter element, filter grade max. 40
matic fuel oil air vent valve (see page 12).
Fit the filter as near as possible to the lower edge
of the boiler (on l.h. or r.h. side) to leave the flexi-
ble oil lines inside the boiler long enough to
remove the burner.
8
380
K
F
¾
G
H
K
3. Prepare the electrical connections.
m) with auto-
µ
For on-site preparation of the water and electri-
cal connections, see the installation instructions
for the pre-plumbing jig or mounting frame.
Filling/draining
Wiring area
Dimension for installation with DHW cylinder below
the boiler
Condensate drain
Power cable: NYM-J 3 x 1.5 mm
ing 16 A, 230 V/50 Hz
Accessory cables: NYM with required number of
cores for external connections
All cables in area "
" should protrude 1200 mm
G
from the wall
2
, max. fuse rat-