5.3.4 INSTALLATION PARAMETERS

Key sequence to access the installation menu
-
During the modification of the parameters, the symbol
-
Use the MODE key to change various parameters.
-
With the buttons
-
To memorise the values press the button "SET". The symbol
appear on the screen for a few seconds to show that the data has been saved.
DESCR
PARAMETER
MENU
DISPLAY
TIP O
Pump type
SCA
Type of exchange
50
it is possible to modify the values.
NAME
Identifies whether the pump is part of a unit or whether it is a
single pump, possible values:
NCON: pump not configured (factory setting)
SING: single pump
PRI: primary or master pump for a unit
SEC: secondary or slave pump for a unit
This parameter indicates the mode used to change pumps when
the pump is part of a unit (PRI, SEC).
CH01: Indicates that the first pump to come on at the next request
for water will be the one which started-up second or which did not
start-up during the last cycle. The second pump cannot support
the first in this mode (BOOSTER setting).
CH02: Indicates that the first pump to come on at the next request
for water will be the one which did not start up during the last
cycle. The second pump cannot support the first in this mode.
CH03: Indicates that the first pump to come on at the next request
for water will be the one which has run for the least amount of
time (see functioning hours parameter). The second pump cannot
support the first in this mode (BOOSTER setting).
CH04: Indicates that the first pump to come on at the next request
for water will be the one which has run for the least amount of
time (see functioning hours parameter). The second pump cannot
support the first in this mode.
CH05: In this setting, the first pump to start-up is the one entered
as the primary pump in the "type of pump" parameter. The second
pump can support the first in this mode; however, the cyclical
function is not available..
Active values for the circulator or circulation pump: CH2 and CH4
Page 20 of 21
20 - GB -
Last button pressed for 10 seconds
on the display lights up.
disappears The words "REC" will
DESCRIPTION
20
DEF
MIN
MAX
SING
N.A.
N.A.
01
01
05

Advertisement