Signals, Alarm Status And Errors; History (Saved); Signal Table - Pentair Pool Products Nocchi R4TE Use And Maintenance Manual

Table of Contents

Advertisement

6

SIGNALS, ALARM STATUS AND ERRORS

6.1

HISTORY (SAVED)

Key sequence
Press ESC for 5 seconds
Key sequence
Press MODE to scroll the error log
Key sequence
Press STOP to see the hour and the date of the event
(when the clock has been set correctly)
6.2

SIGNAL TABLE

MESS
DISPLAY
System
signal
INIT
System re-initiation
REIN
signal
Inhibit intervention
INB
signal
Reset configuration
RPC
Save parameters in the memory
REC
Total reset signal
RST
AUTO
AdAP
function signal
Memory reset
RSE
Memory
ESG
carried out
End of alarm (in
FAL
memory)
Maximum
complementary
TOP
pump
Complementary
ON
pump on
Complementary
STB
pump on standby
54
DESCRIPTION
initiation
The condition occurs when the
system is first started-up or after a
prolonged power failure
The condition occurs when a
short power failure takes place
This is an operative condition
generated
by
command which closes entry to
the inhibitors. (NO – NC)
The board has been reset. The cause of this signal can be a either
prolonged absence of power or if the reset button has been pressed
manually. The module will save all the information recorded, with the
exception of clock setting.
learning
The control has an active AUTO learning function and is auto-adjusting
the set point.
The eeprom memory has been reset (see chapter 7.2). The module
returns to the factory settings
reset
Confirms that the eeprom memory has been reset (see chapter 7.2).
Indicates the end of an alarm.
power
The complementary pump is on at the maximum frequency possible.
The complementary pump is on and regulating.
The complementary pump is on standby.
Page 24 of 25
24 - GB -
Push ESC button
Push MODE button
Push STOP button
Wait for a change in status
Check
an
external
command
pressure gauge).
24
ACTION
the
external
inhibitor
(i.e.
switch,
float,

Advertisement