Figure 4-2
Arrangement of the lifting eyebolts for 1PV513x/1FV513x
Figure 4-3
Location of the lifting eyebolts for the 1FV516x
Transporting a motor that has already been in operation
If you want to transport a motor that has already been in operation, proceed as follows:
1. Allow the motor to cool down.
2. Remove the connections provided by the customer.
3. Empty the motor of any cooling water and purge it carefully with air.
4. Close and seal all openings on the terminal box and housing.
5. Always transport and lift the motor by the lifting eyebolts on the bearing end shields.
SIMOTICS A-1FV5/1PV5 synchronous/induction motors
Operating Instructions, 03/2014, 610.45002.40
Preparing for use
4.2 Transport and storage
25