4.5 Application Presets
WARNING! Confirm the drive I/O signals and external sequence before starting test run. Setting parameter
A1-06 may change the I/O terminal function automatically from the factory setting. Failure to comply may
result in death or serious injury.
Perform a 2-wire or 3-wire initialization (A1-03 = 2220 or 3330) on the drive before
selecting one of the application presets or before switching between application presets. The
initialization process should reset drive parameters before using an application preset.
Save user-edited parameters to a list by setting o2-03 to "1". This allows for more immediate
access a specific list of relevant parameters and saves time scrolling through the parameter
menu items.
Set the parameter access level for Preferred Parameters (A1-01 = "1") to display only the
setup parameters.
The parameters listed in the table below are unaffected by drive initialization:
No.
A1-02
<1>
C6-01
E1-03
E5-01
o2-04
<1> The control method set to A1-02 is unaffected when performing a 2-wire or 3-wire intialization, but it
automatically changes according to the value set to parameter A1-06.

Related Parameters

No.
Parameter Name
Access Level
A1-01
Selection
A1-03
Initialize Parameters
A2-02
User Parameters,
to
2 to 32
A2-32
112
0: Operation only
1: User Parameters (access to a set of parameters selected by the
user)
2: Advanced Access Level
0: No Initialize
1110: User Initialize (The user must first set user parameter values
and then store them using parameter o2-03)
2220: 2-Wire Initialization
3330: 3-Wire Initialization
4440: DriveWorksEZ Initialization
5550: OPE04 Error Reset
b1-01 to o2-08
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Parameter Name
Control Method Selection
Duty Selection
V/f Pattern Selection
Motor Code Selection (for PM motors)
Drive/kVA Selection
Setting Range
Default
2
<1>
0
<1>