Pause
To bring the hose and gun back to spray temperature
after a brief break, use the following procedure.
1. Engage the piston safety lock or trigger safety lock.
Fusion
2. Set the function knob to Slow Recirc
-
-
STATUS
2
3
1
4
0
5
6
+
7
8
-
9
10
3. Set the Spray valves to Recirc until the temperature
readouts come back up.
NOTE: If you stop spraying for more than 2 minutes
when using an impingement mix gun, close gun fluid
valves. Doing this will keep the internal parts of the gun
cleaner and prevent crossover.
Fusion
332144H
Probler
.
-
-
STATUS
2
3
1
4
0
5
OR
6
+
7
8
-
9
10
ti21489a
ti21495a
Probler
Refill Tanks
Material can be added to the tanks at any time. See Fill
Fluid Tanks, page 18.
If you are operating at high temperatures or flow rates,
follow Pause instructions, page 23, to bring the tanks up
to temperature.
To prevent cross-contamination of fluids and
equipment parts, never interchange ISO and RES
parts or containers.
Have at least two 5 gal. (19 liter) pails to transfer fluid
from drums to supply tanks. Label one pail "ISO" and
the other "RES", using the red and blue labels
provided. Always double-check which material you
have before pouring it in the supply tanks. Pouring is
easier if pails are not filled to the top.
Open only one supply tank at a time, to avoid splashing
material from one tank into the other when filling.
Operation
NOTICE
23