Heatup Guidelines
The fluids must be circulated from the pumps through
the heater, hoses, and back to the tanks to ensure warm
fluids are supplied to the gun.
Slow Recirculation
•
Slow Recirc results in a higher temperature transfer
in the heater, so hoses and gun heat up quicker.
•
Good for touchup or low flow spraying, up to
moderate temperature.
Fast Recirculation
Fast Recirc keeps heaters on full-time to bring fluid
tanks up to temperature. The higher your flow rate, the
more heat needed in the tanks before spraying.
•
For 200-240VAC systems: Use Fast Recirc until
the pump inlet fluid temperature gauges (Y) are
within 45°F (25°C) of target outlet temperature.
•
For 100-120VAC systems: Use Fast Recirc until
the pump inlet fluid temperature gauges (Y) are
within 30°F (17°C) of target temperature.
•
Volume in tanks: Use only what you need. For
example, 2.5 gal. (10 l) in each tank will heat up
almost twice as fast as 5 gal. (20 l).
•
Mixes fluid within tanks, to avoid heating only the
fluid at the top of the tank.
•
Use for flushing.
332144H
Heat Management Tips
•
Heaters perform better with lower flow rates or
smaller mix modules.
•
Triggering the gun for short periods helps maintain
efficient heat transfer, keeping material at the
desired temperature. Triggering the gun for a long
period may not allow enough heating time,
depending on material temperature in tanks.
•
If the temperature displays fall below acceptable
limits, set the function knob to Slow Recirc
circulate again to bring temperatures back up.
•
Each 35 ft (10.7 m) hose bundle adds about 5
minutes to heatup time, with most materials. The
maximum recommended hose length is 105 ft (32
m).
•
For a quicker start, do initial heatup circulation with
the tanks 1/4 to 1/3 filled, then add more material.