Technical Specifications

Technical Specifications
Reactor E-10hp
Maximum fluid working pressure
Maximum spray pressure: 120 V
Maximum spray pressure: 230 V
Maximum fluid temperature
Maximum ambient temperature
Maximum output
Output per cycle (ISO and RES)
Air inlet
Air outlet
Overpressure relief
Gun compressed air requirements
Maximum hose length
Tank capacity each (nominal)
Weight (empty)
Recommended Mix Chamber Sizes
®
Fusion
Air Purge
®
Probler
P2
Electrical Requirements
120 V
230 V
Generator Size
120 V
230 V
Heater Power
120 V
230 V
Sound Pressure
In fast recirculation mode
Measure at 2500 psi (17 MPa, 172
bar), 1 gpm (3.8 lpm)
74
US
3000 psi
2200 psi
2500 psi
170°F
120°F
1 gal./min
0.0038 gallons/cycle
1/4 in. quick-disconnect industrial type pin fitting
1/4 npsm(m)
Spray valves automatically relieve excessive fluid pressure back to supply
tanks
Fusion Gun (purge air and operating air): 4 scfm (0.112 m
105 ft
6 gal.
239 lb
000, AW2222 (00 and 01 at reduced spray pressure)
AA (00 and 01 at reduced spray pressure)
100-120VAC, 1 phase, 50/60 Hz, 3840 W; requires two separate,
dedicated 20 A circuits. Full load peak amperage 16 A per circuit.
200-240VAC, 1 phase, 50/60 Hz, 5520 W; requires two separate,
dedicated 15 A circuits. Full load peak amperage 12 A per circuit.
5000 W minimum
7500 W minimum
3000 W during recirculation, 2000 W during pressure spray mode
4000 W during recirculation, 2760 W during pressure spray mode
Metric
20.6 MPa, 206 bar
15.2 MPa, 152 bar
17.2 MPa, 172 bar
77°C
48°C
3.8 liters/min
0.014 liters/cycle
32 m
22.7 liters
108 kg
71.3 dB(A)
85.6 dB(A)
3
/min)
332144H