Grounding

The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Reactor: grounded through the power cord.
Generator (if used): follow your local code. Start and
stop the generator with the power cord(s) disconnected.
Spray gun: grounded through the supplied fluid hoses,
connected to a properly grounded Reactor. Do not
operate without at least one grounded fluid hose.
Object being sprayed: follow your local code.
Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place pail on a
nonconductive surface, such as paper, plastic, or
cardboard, which interrupts grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold a metal part of spray gun
firmly to the side of a grounded metal pail, then trigger
gun.

Connect Fluid Hoses

1. Connect the fluid supply hoses to the outlet hose
connections (R, F
IG
RES. Fittings are sized to prevent connection
errors. Connect the other end of hoses to ISO and
RES inputs of gun.
NOTE: Probler guns use a Probler P2 recirculation
accessory kit.
332144H
. 5). Red hoses for ISO, blue for
2. Connect the recirculation hoses from the gun
recirculation ports to the connections (S).
(RES)
F
. 5 Connect the Recirculation Hoses
IG

Connect Gun Air Hose

1. Connect the gun air hose to the gun air input and to
the air filter outlet (Z). If you are using more than
one hose bundle, join the air hoses with the nipple
provided with the hose bundle.
2. On units with Fusion guns, connect the supplied ball
valve and quick-disconnect coupler to the gun air
hose, then connect the coupler to the gun air fitting.

Connect Main Air Supply

Connect the main air supply to the quick disconnect
fitting (Q) on the unit. The air supply hose must be at
least 5/16 in. (8 mm) ID up to 50 ft (15 m) or 3/8 in. (10
mm) ID up to 100 ft (30 m).
NOTE: An air Filter/Moisture Separator (Z) is equipped
with an automatic moisture drain.

Flush Before First Use

The Reactor is tested with a plasticizer oil at the factory.
Flush out the oil with a compatible solvent before
spraying. See Flushing, page 26.
Setup
S
R
ti21488A
R
S
(ISO)
ti6988b
Air
17