Appliance functions
Temperature profile 5
50
40
30
20
10
1
5
10
Fig. 66
Temperature profile 6
60
50
40
30
20
10
1
5
10
Fig. 67
Ends after 21 days.
Raising the reduced room temperature
During operation at reduced room temperature, the
reduced set room temperature can be automatically
raised subject to the outside temperature. The temper-
ature is raised in accordance with the selected heating
curve, and no higher than the standard set room tem-
perature or comfort room temperature. Depending on
which set room temperature will become active in the
next time phase.
(cont.)
15
20
25
Days
15
20
25
30
Days
30
The outside temperature limits for the start and end of
temperature raising can be set in parameters 1139.0
and 1139.1.
Function description
111