Electrical connections
Fig. 23
Bundle cables using the supplied cable clips.
Route extra low voltage (ELV) leads < 42 V separately
from cables
42 V/230 V~.
>
Secure the cable clips on the underside using the sup-
plied screws.
Do not route cables over sharp edges.
!
Please note
If connecting cables/leads come into contact
with hot components, they will be damaged.
When routing and securing cables/leads on site,
ensure that the maximum permissible tempera-
tures for these cables/leads are not exceeded.

WiFi operational reliability and system requirements

WiFi router system requirement
WiFi router with activated WiFi:
The WiFi router must be protected by a sufficiently
secure WPA2 password.
The WiFi router must always have the latest firm-
ware update.
Do not use unencrypted connections between the
heat generator and the WiFi router.
Internet connection with high availability:
Flat rate (flat rate tariff without restriction on time or
data volume)
(cont.)
Dynamic IP addressing (DHCP, delivered condition)
in the network (WiFi):
Have this checked on site, and if required set up, by
an IT expert prior to commissioning.
Set routing and security parameters in the IP net-
work (LAN):
Enable port 80, port 123, port 443 and port 8883 for
direct outward connections.
Have this checked and, if necessary, set up on site
by an IT expert before commissioning.