Viessmann Vitodens 200-W B2HE Installation And Service Instructions Manual page 90

Wall mounted gas condensing boiler
Hide thumbs Also See for Vitodens 200-W B2HE:
Table of Contents

Advertisement

Troubleshooting
Fault messages
(cont.)
Fault number
System characteristics
on the display
F.400
Burner in a fault state
F.401
Burner in a fault state
F.402
Burner in a fault state
F.403
Burner in a fault state
F.404
Burner in a fault state
F.405
Burner in a fault state
F.406
Burner in a fault state
F.407
Burner in a fault state
F.408
Burner in a fault state
F.410
Burner in a fault state
F.416
Burner blocked
F.417
Burner in a fault state
F.418
Burner blocked
F.425
System in control mode, cal-
culation out of operation
F.426
Burner in a fault state
F.427
Burner in a fault state
F.428
Control mode
F.429
Control mode
90
Cause
Lead break, ionisation
voltage, signal 1
Short circuit, ionisation
voltage, signal 2
Lead break, ionisation
voltage, signal 2
Short circuit, dynamic ioni-
sation current, signal 1
Lead break, dynamic ioni-
sation current, signal 1
Short circuit, dynamic ioni-
sation current, signal 2
Lead break, dynamic ioni-
sation current, signal 2
Safety chain
Gas valve monitoring re-
lay 1 has responded
Internal error, processor,
BCU burner control unit
Flue gas temperature sen-
sor incorrectly positioned
Short circuit, 24 V power
supply
Lead break, 24 V power
supply
Time synchronisation
failed.
Short circuit, external un-
lock signal
Lead break, external un-
lock signal
Short circuit, air mass
sensor, fan unit
Lead break, air mass sen-
sor, fan unit
Measures
Check ionisation electrode and
connecting cable.
Reset device.
Check ionisation electrode and
connecting cable.
Reset device.
Check ionisation electrode and
connecting cable.
Reset device.
Check ionisation electrode and
connecting cable.
Reset device.
Check ionisation electrode and
connecting cable.
Reset device.
Check ionisation electrode and
connecting cable.
Reset device.
Check ionisation electrode and
connecting cable.
Reset device.
Check heating system fill level.
Check circulation pump.
Vent the system.
Reset device.
Reset device.
Reset device.
Fit flue gas temperature sensor
correctly. See "Repairs".
Check connecting cable and sup-
ply voltage to the BCU burner con-
trol unit.
Reset device.
Check connecting cable and sup-
ply voltage to the BCU burner con-
trol unit.
Reset device.
Set the time. If external time is
used, check parameters 1504 and
508.
Check the connection to the HMU
heat management unit.
Reset device.
Check the connection to HMU heat
management unit.
Reset device.
Check connecting cable and plug-
in connector.
Check connecting cable and plug-
in connector.