K1: Mode group, channel, program operation, reset response
9.9 Program operation
9.9.13

Influencing the Stop events through Stop delay area

Stop delay area
The reaction to a stop event can be influenced by the conditioned interruptible area in the
current part program. Such a program area is called stop delay area.
Within the stop delay areas there should be no stop and the feed should not be changed. Stops
do not take effect until the program section has been completed (Example: Making of a thread).
A stop delay area is defined with the part program commands:
DELAYFSTON
DELAYFSTOF
References:
Programming Manual, Job Planning
Stop events
Overview of the NCK events that cause a stop:
NCK events
Reset and mode group RESET
PROG_END
Interrupt
DELDISTOGO_SYNC
PROGRESETREPEAT
PROGCANCELSUB
SINGLEBLOCKSTOP
SINGLEBLOCK_IPO
SINGLEBLOCK_DECODIER
STOPALL
STOPPROG
OVERSTORE_BUFFER_END_REACHED
PREP_STOP
PROG_STOP
STOPPROGATBLOCKEND
STOPPROGATSUPEND
WAITM
WAITE
INIT_SYNC
MMCCMD
556
Start of a stop delay area
End of a stop delay area
Reaction
Stop criteria
Immediate
IS: DB21, ... DBX7.7 and DB11 DBX20.7
Alarm 16954
NC prog.: M30
Delayed
IS: "FC-9" and ASUB DB10 DBB1
Immediate
IS: "Delete distance-to-go" DB21, ... DBX6.2 and axial
Delayed
IS: "Clear number of subprogram passes" DB21, ...
DBX6.3
Delayed
IS: "Program level abort" DB21, ... DBX6.4
Delayed
In the stop delay area: NC stops at the end of the 1st block
outside the stop delay area.
Single block is active before the stop delay area:
IS: "NC Stop at block limit" DB21, ... DBX7.2
Delayed
IS: "Activate single-block type 1" DB11 DBX21.7
Delayed
IS: "Activate single-block type 2" DB11 DBX21.6
Immediate
IS: DB21, ... DBX7.4 and DB11 DBX20.6
Delayed
IS: DB21, ... DBX7.3 and DB11 DBX20.5
Alarm 16954
NC prog.: Stop because of empty overstore buffer
Alarm 16954
NC prog.: STOPRE and all implicit Stopres
Alarm 16954
NC prog.: M0 and M1
Delayed
IS: "NC Stop at block limit" DB21, ... DBX7.2
System fault
Subprogram end should always deselect the stop delay
area.
Alarm 16954
NC prog.: WAITM
Alarm 16954
NC prog.: WAITE
Alarm 16954
NC prog.: INIT with parameter "S"
Alarm 16954
NC prog.: MMC( STRING, CHAR )