K1: Mode group, channel, program operation, reset response
9.14 Program control
Examples
Comparisons between display block (original block) and basic block display:
● Programmed positions are displayed as absolute.
The addresses AP/RP are displayed with their programmed values.
Original block:
N10 G90 X10.123
N20 G91 X1
● Address assignments (non-DIN addresses) are displayed in the form <address> =
<constant>.
Original block:
N110 R1 = -67.5 R2 = 7.5
N130 Z = R1 RND = R2
● Address indices (address extensions) are displayed as constants <address> [ <constant> ]
= <constant>.
Original block:
N220 DEF AXIS AXIS_VAR = X
N240 FA[ AXIS_VAR] = R2
● DIN addresses without address extension are displayed in the form
<din_address> <constant>.
Original block:
N410 DEF REAL FEED = 1.5
N420 F = FEED
596
Display block:
N10 X10.123
N20 X11.123
Display block:
N130 Z-67.5 RND = 7.5
Display block:
N240 FA[X] = 1000
Display block:
N420 F1.5
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Basic Functions