Block Change Delay; Data Lists; Machine Data; General Machine Data - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

4.9.2

Block change delay

Even if all path axes and special axes traversing in the part program block have satisfied their
specific block transition criteria, the block change can still be delayed due to other unsatisfied
conditions and/or active functions:
Examples:
● Missing auxiliary function acknowledgement by the PLC
● Non-existent following blocks
● Active function "Empty buffer"
Effects
If a block change cannot be executed in continuous path mode, all axes programmed in this
part program block (except cross-block traversing special axes) are stopped. In this case,
contour errors do not occur.
The stopping of path axes during machining can cause undercuts on the workpiece surface.
4.10

Data lists

4.10.1

Machine data

4.10.1.1

General machine data

Number
Identifier: $MN_
10110
PLC_CYCLE_TIME_AVERAGE
10680
MIN_CONTOUR_SAMPLING_TIME
10682
CONTOUR_SAMPLING_FACTOR
10712
NC_USER_CODE_CONF_NAME_TAB
12030
OVR_FACTOR_FEEDRATE
12100
OVR_FACTOR_LIMIT_BIN
18360
MM_EXT_PROG_BUFFER_SIZE
4.10.1.2

Channelspecific machine data

Number
Identifier: $MC_
20150
GCODE_RESET_VALUES
20170
COMPRESS_BLOCK_PATH_LIMIT
20172
COMPRESS_VELO_TOL
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
B1: Continuous-path mode, Exact stop, Look Ahead
Description
Average PLC acknowledgment time
Minimum contour sampling time
Contour sampling factor
List of reconfigured NC commands
Evaluation of the path feed override switch
Limit for binarycoded override switch
FIFO buffer size for execution from external source
(DRAM)
Description
Initial setting of the groups
Maximum traversing length of NC block for compres‐
sion
Maximum permissible deviation from path feed for com‐
pression
4.10 Data lists
239

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents