6 BASIC INSTRUCTIONS
[Operation Errors]
(1) There are no operation errors associated with the DI and EI instructions.
(2) There are no operation errors associated with the IMASK instruction.
[Program Example]
(1) The following program creates an execution enabled state for the interrupt program marked by
the interrupt pointer number when X0 is ON.
[Ladder Mode]
6 - 108
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
[List Mode]
Steps
Instruction
MELSEC-Q/QnA
Device
6 - 108