06 - 08
Present Fault Record
06 - 09
Second Most Recent Fault Record
Third Most Recent Fault Record
06 - 10
06 - 11

Fourth Recent Fault Record

Readings
5-76
00
No fault
01
Over-current (oc)
02
Over-voltage (ov)
03
Overheat (oH)
04
Overload (oL)
05
Overload1 (oL1)
06
External fault (EF)
07
IGBT protection (occ)
08
CPU failure (cF3)
09
Hardware protection failure (HPF)
10
Current exceeds 2 times rated current during accel.(ocA)
11
Current exceeds 2 times rated current during decel.(ocd)
12
Current exceeds 2 times rated current during steady state operation (ocn)
13
Ground fault (GFF)
14
Reserved
15
CPU READ failure (CF1)
16
CPU WRITE failure (CF2)
17
Reserved
18
Motor over load (oL2)
19
Auto accel/decel failure (CFA)
20
Software/password protection (codE)
21
Emergency stop (EF1)
22
Phase-Loss (PHL)
23
Preliminary count value attained, EF active (cEF)
24
Under-current (Lc)
25
Analog feedback signal error (AnLEr)
26
PG feedback signal error (PGErr)
Factory Setting: 00