5. Remove two (2) flat head screws attaching limit
module to aluminum plate.
G2: Use 1.5mm hex driver
G3: Use T6 Torx® or Torx Plus® driver
Reassembly
1. Install new limit module using screws appropriate
to housing (G2 hex socket, G3 Torx®). Make sure
limit housing is oriented correctly.
Note:
Be careful not to strip module attachment
screws. Very little torque is needed to attach
hosing.
2. Connect cable module wiring to limit module.
Check that connection is secure:
G2: Latch should click in place
G3: Connector should be fully engaged and flush
with connector housing.
Note:
If replacing a G2 module with a G3 unit an
adapter cable is required and should have been
included with your replacement limit/home
module. Please contact factory if cable is missing.
Chapter 6 - Maintenance and Lubrication
3. When attaching the cover plate with limit module to
the carriage connector assembly ensure that black
G2 connector is flat and located as shown below.
Remainder of reassembly is reverse of
disassembly steps 1-3.