*While the instructions in the following procedure show cable options that
are no longer available, the procedure itself is still accurate.
1. Remove two (2) M3 button head cap screws using
a 2mm hex key. Remove the silver back cover
from the connector block.
Caution!
Do not use a ball nose driver until the
screws are broken loose as the button head screw
hex interface is easily striped.
2. Using a 3mm ball nose hex key loosen but do not
remove the two (2) screws found inside the
connector hosing.
Chapter 6 - Maintenance and Lubrication
3. Loosen the M4 button head screw using a 2.5mm
hex key. Slide the cable carrier hold clamp off of
the cable carrier support. Mark or take careful
note of which cable support the hold down is
attached to for reinstallation.
4. Using a 2mm hex key. Remove the two (2) flat
head screw on the top of the carriage connector
module.
Caution!
Do not use a ball nose driver until the
screws are broken loose as the flat head screw
hex interface is easily striped.