Internal Access Procedure for travels > 1250mm
1. Remove carriage end caps by removing four (4)
hex socket shoulder screws with compression
spring preload (2 per end cap) using a 2.5 mm
hex key.
Chapter 6 - Maintenance and Lubrication
2. Measure gap between top (crown) of center cover
and bottom of carriage when carriage is at center
of travel. Write down this measurement. You will
need to match this dimension when reassembling
the positioner.
3. Remove all four (4) strip seals clamps by removing
eight (8) M3 Button Head Cap Screws using a 2
mm hex key.
Caution!
Do not use a ball nose driver as the
button head screw hex interface is easily striped.