Navigation menus (1/2)
Filtration
Filtration: AUTO, SHOCK, TIMER, OFF, ON
Start: 07:00
End: Auto
mode: Eco, Normal, Turbo
ORP priority: ON, OFF
Frost prevention: +3 °C
Algorithm: t=T VS, BlueVS, T/2Cla, BluCla
Eco mode: -30%
Turbo mode: +30%
Flow switch: YES, NO
Filter washing
Manual washing: 'Valid' to start washing
Washing: 70 secs
Rinsing: 20 secs
Disinfectant
mode: AUTO, OFF
Probe: REDOX, CHLORINE, BROMINE, PEROXIDE
Set point: 650 mV (REDOX probe mode)
or
Set point: 1.0 mg/L (CHLORINE, BROMINE, PEROXIDE probe mode)
Proportional: YES, NO (CHLORINE, BROMINE, PEROXIDE probe mode)
Type: PUMP, ELECTROLYSIS, PEROXIDE, WEEK, DAY
Stop threshold: 16 °C
Injection: 15 sec (every 15 m) (PUMP mode type)
Pool Pool: 48M3 (PEROXIDE mode type)
Dos. pump: 1.0 L/h (PEROXIDE mode type)
Vol/week: 0.4 L (Mode Type PEROXYDE)
Comp. Temp.: 1.0 (PEROXIDE mode type)
Max. volume: 0.5 L/day (PEROXIDE mode type & PUMP type only)
Alert range: 100 (if the set point is 650 mV, minimum alert = 650-100 = 550 mV, maximum alert = 650+100 = 750 mV)
Priming: ACTIVE (while OK button is held down)
pH
mode: AUTO, OFF
Set point: 7.2
Type: pH-, pH+
Stop threshold: 3 °C
Injection: 15 secs (every 15 mins)
Max. volume: 0.5 L/d
Alert range: 0.2 (if the set point is 7.2, minimum alert = 7.2-0.2 = 7.0, maximum alert = 7.2+0.2=7.4)
Priming: ACTIVE (while OK button is held down)