Wall fixing
- This device is intended to be used inside, installed in a technical room which cannot be accessed by
children.
- Set the device at a height lower than 2 m using three screws (4 to 5 mm diameter) in appropriate plugs
for the type of support and fix the device vertically on a clean support which is able to bear a minimum
vertical load of 5 kg.
Pierce three holes in accordance with the below dimensions then place 3 suitable plugs.
1 - Tighten the screw at the top, leaving 2 mm under the screw head, then hang the device on this.
2 - Place the 2 lower screws.
3 - Add the 2 lower screw covers to ensure a full seal.
1
Basis for settings in an existing installation
The 3-position switch is
kept.
It makes it possible to
rinse the filter using the
positions FORCED
OPERATION/STOP. If used
with SOLEO, position on
CLOCK.
Back of the device
185 mm
08
2
FILTRATION
SOLEO
FORCED OPERATION
F I LT R AT I O N ,
15:15 Water:+28.4°C
Filtration : ON
Chlorine : 13.1mg/L
Air:+27.9°C pH: 7.3
STOP
ESC
AUTO-CLOCK
Location of the screw head
Distance between the two locking screws
and fastening screw
Distance between the two locking screws
Caps
(Do not remove)
3
SOLEO CL is connected to a
CHLORINE
®
classic electrical installation.
P H
&
O R P
All of the outlets are dry
VALID
contacts which are normally
open (NO) and can interrupt
up to 230 V-10 A (above this,
add a contactor).