Filtration - connection and settings
If SOLEO CL is linked to a SPEEDEO, the SOLEO CL filtration outlet is only supplied with power when
SPEEDEO starts the VS pump (whatever the speed). This SOLEO CL filtration outlet can for example be
used to supply a UV light.
New installation:
PHASE (L)
EARTH
NEUTRAL (N)
Existing installation:
Parallel connection with the contact of
the filtration programmer. > Place the
pins into inactive position (OFF).
PHASE (L)
EARTH
NEUTRAL (N)
Home menu > Filtration menu:
-Fi l tratio n : O N
Sta r t : 07 : 0 0
Stop : AUTO
M od e : E CO
Mode: This setting increases or
decreases the filtration time to
compensate for the size of the
pump
and/or
activity
swimming pool. Factor y settings:
Turbo = +30%, Eco = -30% (can be
modified in the Instal. menu).
FORCED
OPERATION
A1
A2
M
A1
A2
Filtration:
Auto = Automatically calculates the filtration duration according to the water
temperature.
On = The filtration runs 24/7.
Off = The filtration is stopped (attention: the freeze-protection mode becomes
inactive).
Timer = The filtration will run during the chosen timeframe from start to finish.
Shock = The Shock function triggers 24 hours of forced filtration and electrolysis.
This function can be useful after the pool has been used by many visitors and when
in
the
the pool temperature is high. At the end of Shock mode, SOLEO returns to Auto mode.
If the Timer mode is activated, the line 'Stop:' appears and gives you control of the
filtration start and end time, to control the level of noise linked to your pool (filtration
noise). By default, leave Stop on Auto.