Water and air temperature probes.
SOLEO CL is supplied with a temperature probe which will be assigned to the water. It is possible to mount
a second temperature probe for the air temperature used to manage the frost protection process of heated
technical rooms.
INSTALLATION OF THE WATER TEMPERATURE PROBE
The temperature probe can be installed outside the bypass in front of the filter of the pump or in
front of the filter inlet in order to improve the reading precision.
1 - Pierce the PVC pipe (diam. 50-70 mm) to a diameter of 10 mm (3/8 inch).
2 - Remove the burrs and check the O-ring under the probe.
3 - Place the sensor in the hole, then place the clamp band in the groove and tighten.
Ø 10 mm
1
INSTALLATION OF THE AIR TEMPERATURE PROBE (OPTION)
- If the air temperature probe is connected, it automatically becomes the reference value for the management
of the anti-freeze protection. The air temperature probe is placed outdoors, away from direct sunlight so that
the measurement is not distorted. It can be easily moved due to its 6 m long cable.
1 – Mount it on a wall by using screws.
2 – Mount it on a horizontal bar of a grate by using a cable tie.
NO
1
10
OK
2
2
The air temperature probe is parallel
connected with the Flow Switch Filtration
inlet.
- When the filtration runs, the flow switch
signal is the one taken into account.
Therefore the swimming pool cannot
freeze.
- When the filtration is not on, the air
temperature is the one being measured. If
it reaches the preset lower limit, then the
filtration is started for 60 minutes before a
new temperature measurement is taken.
After 15 minutes, the filtration is started if
the air temperature is still below the
designated threshold.