Filtration - Expert menu
- Secured Install menu (on the main menu, press Esc and Valid at the same time for 3 secs. A star appears in the top
right corner of the home screen). This menu, active for 15 min., makes it possible to access the more sensitive functions
which are set when the device is put into service.
Home Menu > Filtration instal. menu:
M o de: E CO
OR P p r io r i t y : ON
Ant ifree ze : +3°C
Eco m od e : - 3 0 %
Tur b o m ode : +30%
This setting makes it possible to modify
the percentage of increase or
reduction of the filtration time from 0
to 99%. (Factory settings; Turbo =
+30%, Eco = -30%).
14
To achieve the RedOx (ORP) set point, the filtration will start in 1 hour cycles
outside of the authorised hours (because this equipment needs to function
when the filtration is on). This function only works in ORP default mode.
Below this temperature, the filtration runs 24/7 to prevent the pool from
freezing (active wintering).
- If the air temperature probe is connected: this will be the reference value for
managing the freeze protection. Place it outdoors, out of direct sunlight so
that the measurements are not distorted (see p06).
- If the air temperature probe is not connected: it is the water temperature
probe which becomes the reference value for managing the freeze protection.
Please check that the technical room is not heated or has a significantly
different temperature in comparison with the temperature outside. If this is
the case, adding the temperature difference at +3.0°C is appropriate to
compensate for this difference.