Start­up
NOTICE
Material damage
Risk of damage to the gear unit through missing or insufficient ventilation.
Replace the screw plug with the air filter or wet­air filter before start­up.
NOTICE
Material damage
Risk of damage to the wet­air filter.
Prior to using the wet­air filter, 2 of the 8 sealed bores at the underside of the wet­air filter must be opened.
Check the oil level of the gear unit (see item 7.5.1).
7.5.1

Oil level

The following oil level is correct:
─ MAX mark on the dipstick with the insert shaft run out.
Note
When cooled down the oil must come up as far as between the MAX mark on the dipstick.
Hot oil may slightly exceed the MAX mark on the dipstick.
NOTICE
Material damage
Insufficient lubrication possible through too low oil level.
Check the oil level.
Under no circumstances must it fall below the MIN mark on the dipstick. If necessary, top up oil to the
correct level.
7.5.2

Temperature measurement

During the first start­up and after maintenance work, the oil­sump temperature must be measured during
proper use (maximum driven­machine performance) after warming up.
NOTICE
Material damage
Risk of damage to the gear unit through insufficient lubrication resulting from too high oil temperature.
The maximum permissible oil­sump temperature is 90 °C.
At higher temperatures the gear unit must be shut down immediately and Siemens customer service
consulted.