10.2.2 Changing the oil (main gear unit)
As an alternative to the oilchange intervals specified in table 11 (see item 10.1), it is possible to have an
oil sample tested at regular intervals, every 4 weeks, by the technical service of the relevant oil company
and to have it cleared for further use.
If further usability has been confirmed, no oil change will be necessary.
Note
Please observe the separately annexed operating instructions BA 7300 and the notes in item 7.1.
•
Drain the oil while the gear unit is still warm, i.e. immediately after stopping the machinery.
NOTICE
Material damage
Risk of damage to the gear unit through incorrect lubrication resulting from mixed oils.
When changing the oil, always refill the gear unit with the same type of oil.
Never mix different types of oil and/or oils made by different manufacturers.
The use of synthetic oil is not permissible.
•
Place a suitable container under the oildrain points of the gearunit housing.
•
Open the oildrain cock (4) and drain off the oil into the container. See also fig. 14 or fig. 15 in item 7.1.2.
CAUTION
Risk of scalding
Risk of injury through escaping hot oil.
Wear suitable protective gloves, protective glasses and protective clothing.
Remove any oil spillage immediately with an oilbinding agent.
Note
Check the condition of the sealing ring; the sealing ring is vulcanised onto the oildrain plug. If necessary,
use a new oildrain plug.
•
Shut the oildrain cock (4).
•
Unscrew the dipstick (3) on the oilequalising tank.
•
Fill fresh oil into the gear unit (see item 7.1.3).