Nortel Enterprise 1000 Reference Manual page 116

Succession communication server, circuit card
Table of Contents

Advertisement

Page 116 of 236
Figure 43
E&M Type II signaling patterns – originating party release on a tandem connection
Outgoing calls from CSE 1000 (near-end)
Incoming calls to CSE 1000 (near-end)
Note:
553-3023-211 Standard 1.00 June 2001
NT8D15 E&M Trunk Card
Near-end M/SB leads
Open
Idle
Dial CO/
FX/WATS
O/G tie
trunk disc
Far-end
disc
Far-end
disc
O/G tie
first
trunk disc
first
Near-end M/SB leads
Open
Idle
CO/FX/WATS
Orig-end
disc
COS-no ans sup
CO/FX/WATS ans
Local end may be arranged
for IMM, DDL, or WNK
Far-end seizes
IMM = Immediate start
DDL = Delayed dial
WNK = Wink start
Closed
Near-end
seizes
Go
Stored office DN digits
outpulsed after GO signal
Universal service provided
Stop
by far-end PBX if originating
end is senderized
Far-end ans
Closed
Dial CO/FX/WATS and office DN
disc
CO/FX/WATS end disc first
Orig-end
(ground start only)(COS-ans sup)
disc first
Pseudo-answer supervision
provided approx. 150 ms
after last dial pulse
Near-end stores office DN
Ð If ground start trunk, outpulse
toward office after ground
detection
Ð If loop start trunk, outpulse
toward office 1 sec later
553-CSE6266

Advertisement