7 Machine Data
7.2
Display machine data for ShopTurn
9621
MD number
Standard value: –1
Change becomes effective after: IMMEDIATELY
Data type: DOUBLE
Significance:
9626
MD number
Standard value: 1
Change becomes effective after: IMMEDIATELY
Data type: WORD
Significance:
9630
MD number
Standard value: 100
Change becomes effective after: IMMEDIATELY
Data type: WORD
Significance:
9639
MD number
Standard value: 1
Change becomes effective after: IMMEDIATELY
Data type: DOUBLE
Significance:
7-54
$MM_CTM_CYCLE_DWELL_TIME
Dwell time for cycles
Min. input limit: –100
Protection level: 3/4
This MD is used to stipulate the dwell time between plunge and retraction for the plunge–
cutting cycles ("Turning" → "Plunge–cutting").
> 0 = Dwell time in seconds
< 0 = Dwell time in spindle revolutions
$MM_CTM_TRACE
Settings for ShopTurn
Min. input limit: 0000
Protection level: 3/4
Bit 0: Free
Bit 1: Display system messages from ShopTurn in the dialog line (for diagnostics purposes
only).
Bit 2 to bit 12: Reserved
Bit 13: Display cyclical lead time of ShopTurn between 1st and 2nd vertical softkey (for
diagnostics purposes only).
Bit 14 to 16: Reserved
$MM_CTM_FIN_SPEED_PERCENT
Finishing feed in percent
Min. input limit: 1
Protection level: 3/4
This MD is used to stipulate a feed rate for the finishing process when complete machining
"Roughing and finishing" is selected; this feed rate is a percentage of the value entered for
parameter F (feed rate).
$MM_CTM_MAX_T OOL_WEAR
Upper input limit for tool wear
Min. input limit: 0
Protection level: 3/4
With this MD you define the upper absolute limit for tool wear (length, radius). This means
that the total value must not exceed the upper absolute limit when entering the wear value
in the tool wear list.
The incremental upper limit is defined in MD 9450 $MM_WRITE_TOA_FINE_LIMIT .
SINUMERIK 840D sl Commissioning Manual CNC: ShopTurn – 11/2006 Edition
Max. input limit: +100
Units:
See meaning
Valid as of software version:
ShopTurn 6.4
Max. input limit: FFFF
Units: Hex
Valid as of software version:
ShopTurn 7.1
Max. input limit: 100
Units: %
Valid as of software version:
ShopTurn 6.1
Max. input limit: 10
Units: mm
Valid as of software version:
ShopTurn 6.4
© Siemens AG 2006 All Rights Reserved