Configuring Lists - Siemens SINUMERIK 840D sl Commissioning Manual

Cnc: shopturn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

11/2006
8.8.2

Configuring lists

Activate the
configuration file
Activate use of
OEM data
Adapt the
configuration file
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D sl Commissioning Manual CNC: ShopTurn – 11/2006 Edition
To modify existing lists (including an integrated additional list) you must proceed
as follows:
Set the following machine data:
MD 9478 $MM_TO_OPTION_MASK, bit 8
Analyze the file TO_TURN.INI
The configuration file TO_TURN.INI, in which you configure changes from the
standard settings, is analyzed (see chapter 8.8.3 "Creating the configuration
file").
If you use user–defined OEM data, set the following machine data:
MD 18080 $MN_MM_TOOL_MANAGEMENT_MASK, Bit 2
Provide memory for user data
MD 18094 $MN_MM_NUM_CC_TDA_PARAM
Number of user–defined parameters
MD 18095 $MN_MM_TYPE_CC_TDA_PARAM[n]=4
Data type (REAL) of user–defined parameters
MD 20310 $MC_TOOL_MANAGEMENT_MASK, Bit 2
Activate user functions
Texts for user–defined parameters (optional)
If you want to change the column headers and cursor texts of the user–defined
parameters, define new texts (see chapter 8.8.7 "Defining texts").
Specify all changes changes with respect to the default settings in the configu-
ration file TO_TURN.INI; (see section 8.8.3 "Creating the configuration file").
8 Tool Management
8.8
Configuring the operator interface
8-111

Hide quick links: