Adjustment Speed Controller Of F5 Lift With "Speed Jump - KEB Combivert F5 Instruction Manual

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

6.

Adjustment Speed Controller of F5 Lift with "speed jump"

1. Open control release (terminal X2A.16)
2. Select closed loop operation
3. Motor without load
4. Set parameters LF.30, LF.31, LF.32 to maximum values
5. Give drive command and measure ru.02/ LI.03 and ru.09/ LI.04
Problem
Solution
Problem
Solution
Problem
Solution
Very long transient process
Increase KP speed (LF.11); eventually
reduce KI spped (LF.12)
Sustained oscillation short billowy,
noises, vibes
Decrease KP speed (LF.11)
Overshoot too long, strong speed
decreases at load change
Increase KI speed (LF.12)
=>
frequency inverter in status „noP"
=>
Parameter LF.10 = 2
Problem
Very long speed overshoot
Solution
Increase KP speed (LF.11); eventually
reduce KI spped (LF.12)
Problem
Transient too slow / remaining system
deviation
Solution
Increase KI speed (LF.12)
Problem
Sustained oscillation long billowy
Solution
Reduce KI speed (LF.12) and / or
reduce KP speed (LF.11)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents