Speed Pro Le - KEB COMBIVERT F5 Applications Manual

Escalator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Escalator
7. Speed Pro le and Timing Chart
Current Check
Acceleration Time
ACTUAL Acceleration Time
Deceleration Time CP17
ACTUAL Deceleration Time
The acceleration and deceleration times (CP16 and CP17) only take into account one jerk time.
Therefore, the ACTUAL accel/decel times must add an additional jerk time and are subject to a
drive reference speed scalar. Default jerk times are set to 5.00 sec. See equation below.
ACTUAL Accel/Decel Time = [(Command RPM/1000) x (CP16 or CP17)] + 5.00 sec.
10
Accel Jerk
Start Jerk
Enable
Speed
Direction
CP16
At Speed
Drive On
Decel Jerk
Stop Jerk