Description of the Unit

2.5.3 Connection F5-Lift for ogive travel with correction input (Lb.05=1, Lb.12=9)

LHF-filter
Bridge
Temperature
switch
+24 V - output
+20...30 V input
GB - 14
Motor-PTC
Control release
K12
Correction input
Direction of travel for-
ward
Direction of travel re-
verse
Setpoint Bit0
Setpoint Bit1
Setpoint Bit2
Free to assign
Braking resistor
++
PE
L1
L2
L3
T1
T2
X2A.16
ST
R1
I6
X2A.17
F
X2A.14
I5
R2
X2A.15
I1
X2A.10
X2A.11
I2
I3
X2A.12
O1
X2A.13
I4
O2
X2A.20
X2A.21
• To switch the control release a relay (K12) must be
used parallel to the safety circuit.
• All 24 V-relays triggered by the inverter must be pro-
tected with diodes.
PB
PE
U
V
W
K1
K2
X3A
Motor encoder
Impulse output/-input
X3B
or SSI-input
Main contactors
X2A.24
X2A.25
X2A.26
Brake
X2A.27
control
X2A.28
X2A.29
X2A.18
X2A.19
X2A.22
X2A.23
M
3~
+24 V
+24 V
ready for operation
Motor and inverter
temperature warning
Ground
Ground