Control terminal strip X2A

1 2 3 4 5 6 7 8 9
Tightening torque 0,22...0,25 Nm
Use shielded / twisted lines
To avoid interferences a separate shield must be provided for analog and digital control lines as well as the
relay outputs
Apply shield to one side of the inverter to the earth potential.
The function of the inputs and outputs depends on the operating mode
PIN Function
1
+ Set value input 1
2
- Setpoint input 1
3
+Pretorque
4
-Pretorque
5
Actual speed
6
Actual torque
7
+10 V - output
8
Analog ground
9
Analog ground
10 Progr. input 1
11 Progr. input 2
12 Progr. input 3
13 Progr. input 4
14 Input up/down
15 Progr. input 5
16 Control release
17 Progr. input 6
18 Transistor output 1
19 Transistor output 2
20 24V output
21 20...30 V input
22 Digital ground
23 Digital ground
24 Relay 1 / NO contact
25 Relay1 / NC contact
26 Relay1 / switching contact
27 Relay 2 / NO contact
28 Relay 2 / NC contact
29 Relay 2 / switching contact
10 11 12 13 14 15 16 17 18 19 20 21 22 23
Name Description
AN1+
Differential voltage input for analog setpoint setting Input voltage:
AN1-
AN2+
Differential voltage input for analog torque control
AN2-
AN-
Output of actual speed
OUT1
0...±10 VDC ^ 0...±maximum speed
AN-
Output of actual torque
OUT2
0...10 VDC ^ 0...maximum torque
Reference voltage output for setpoint potentiome-
CRF
ter
COM
Ground for analog in- and output
COM
I1
Setpoint Bit 0
I2
Setpoint Bit 1
I3
Setpoint Bit 2
I4
prog. mit Lb.13
F
Input for direction of travel up/down
I5
progr. with Lb.11
ST
Output is enabled, error reset upon release
I6
prog. with Lb.12
„Ready for operation"; is set if the unit is initialized
O1
and no error is present, progr. with LB.16 gesetzt
O2
progr. with Lb.17
Uout
Supply voltage for digital inputs and outputs
Uin
Voltage input for external supply, reference potential 0 V
0V
Reference potential for digital inputs/outputs
0V
RLA
Relay output 1, activation of main contactors,
RLB
progr. with Lb.14
RLC
FLA
Relay output 2, brake control,
FLB
progr. with Lb.15
FLC
Description of the Unit
24 25 26 27 28 29
Specifications
0...±10 V DC
Ri: 55 kΩ
Output voltage:
0...±10 V DC
Ri: 100 Ω
Resolution: ±12 Bit
+10 VDC +5 %
max. 4 mA
13...30 VDC ±0 %
smoothed
Ri: 2,1 kΩ
scan time: 1 ms
Imax: 50 mA altoge-
ther for both outputs
Imax: 100 mA
max. 30 V DC
0,01...1 A
GB - 19