Wiring Examples / Flow Charts; Connection F5-Lift For Binary-Coded Setpoint Selection (Factory Setting) - KEB Combivert F5 Instruction Manual

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Description of the Unit
2.5 Wiring examples / flow charts

2.5.1 Connection F5-Lift for binary-coded setpoint selection (factory setting)

LHF-filter
Bridge
Temperature
switch
+24 V - output
+20...30 V input
Setpoint selection
Bit 0
(X2A.10)
0
VR (LF.20)
VL (LF.21)
VN (LF.22)
VI (LF.23)
V1 (LF.24)
V2 (LF.25)
V3 (LF.26)
GB - 10
Motor-PTC
Control release
K12
UPS-operation
Direction of travel for-
ward
Direction of travel re-
verse
Setpoint
binary-coded bit 0
Setpoint
binary-coded bit 1
Setpoint
binary-coded bit 2
Free to assign
Bit 1
Bit 2
(X2A.11)
(X2A.12)
-
-
-
1
-
-
-
1
-
1
1
-
-
-
1
1
-
1
-
1
1
1
1
1
Braking resistor
++
PE
L1
L2
L3
T1
T2
X2A.16
ST
R1
X2A.17
I6
F
X2A.14
I5
R2
X2A.15
I1
X2A.10
I2
X2A.11
X2A.12
I3
O1
I4
O2
X2A.13
X2A.20
X2A.21
• To switch the control release a relay (K12) must be
used parallel to the safety circuit.
• All 24 V-relays triggered by the inverter must be pro-
tected with diodes.
PB
PE
U
V
W
K1
K2
X3A
Motor encoder
Impulse output/-input
X3B
or SSI-input
Main contactors
X2A.24
X2A.25
X2A.26
Brake
X2A.27
control
X2A.28
X2A.29
X2A.18
X2A.19
X2A.22
X2A.23
M
3~
+24 V
+24 V
ready for operation
Motor and inverter
temperature warning
Ground
Ground

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents