2.3

Motor encoder connection X3A

The connection of the motor encoder is done on socket X3A. Which of the encoders can be connected depends
on the installed encoder interface and is displayed in LC.11.
All encoder connectors may be connected / discon-
nected only at switched off frequency inverter and
switched off supply voltage.
The frequency inverter monitores all encoder signals.
If the encoder alarm is activated and no zero track
is existent, connect N- with +5V (PIN12) and N+ with
COM (PIN13).
The encoder alarm can be switched off with LC.03.

2.3.1 Incremental encoder interface

PIN
Name
3
A-
4
B-
8
A+
9
B+
11
+24 V
12
+5 V
13
COM
14
N-
15
N+
-
GND

2.3.2 SIN/COS encoder interface

PIN
Name
1
C-
2
D-
3
A-
4
B-
6
C+
7
D+
8
A+
9
B+
12
+5,25 V
13
COM
14
-R
15
+R
-
GND

2.3.3 Resolver encoder interface

PIN
Name
3
SIN-
4
COS-
5
REF-
8
SIN+
9
COS+
10
REF+
14
GND
-
GND
Description
Differential signal to A+
Differential signal to B+
Incremental encoder track A
Incremental encoder track B
Voltage output 20...30 V
Voltage output 5 V, power supply for the encoders
Reference potential for voltage supply
Difference signal to N+ (if non-existent, assign with +5 V PIN12)
Zero track (if non-existent, assign with COM PIN13)
Connection for shielding at connector housing .
Internally directly connected with inverter earth.
Description
Differential signal to C+
Differential signal to D+
Differential signal to A+
Differential signal to B+
Absolute track for initial position and angular calculation
Absolute track for initial position and angular calculation
Incremental signals A for counter and direction detection
Incremental signals B for counter and direction detection
Power supply for encoder
Reference potential for supply voltage
Differential signal to zero track R+
Zero track
Connection for shielding at connector housing .
Internally directly connected with inverter earth.
Description
Negated sinus signal
Negated cosine signal
Negated field voltage output
Sinus signal
Cosine signal
Field voltage output
Connection for shielding of signal lines
Connection for shielding of the entire cable at the connector housing.
Internally directly connected with inverter earth.
Description of the Unit
X3A
5
4
10
9
8
15
14
13
3
2
1
7
6
12
11
GB - 7